Hook up: Flow measurement
Condition of fluid: gas
Max. operating pressure: PB 420 bar
| Pos. | Qty. | Designation | Part no. | |
| Steel | Stainless steel | |||
| 1 | 1 | Pressure tap | ||
| 2 | 2 | Primary isolation valve PN 420 male / female 1/2-14 NPT |
N354.07.101.05 | N354.07.401.05 |
| 3a | 6 | Male connector 1/2-14 NPT / tube fitting 12S |
S007.53.108.05 | S007.53.208.05 |
| 3b | 6 | Male connector 1/2-14 NPT / twin ferrule compression ends Ø 12 |
choice of customer | |
| 4 | 2 | Impulse line Ø 12 | ||
| 5 | 1 | 3 valve manifold PN 420 both sides female 1/2-14 NPT |
N542.41.184.01 | N542.41.484.01 |
| 6a | 2 | Male connector 1/4-18 NPT / tube fitting 12S |
S007.53.108.05 | S007.53.208.05 |
| 6b | 2 | Male connector 1/4-18 NPT / twin ferrule compression ends Ø 12 |
choice of customer | |
| 7 | 1 | Instrument | ||