Hook up: Flow measurement
Condition of fluid: liquid
Max. operating pressure: PB 400 bar
| Pos. | Qty. | Designation | Part no. | |
| Steel | Stainless steel | |||
| 1 | 1 | Pressure tap outlet: weld end Ø 24 x 7,1 |
S007.56.602.01 | S007.56.202.01 |
| 2 | 2 | Primary isolation valve PN 400 Ø 24 x 7,1 / tube fitting 12S |
S350.05.130.09 | S350.05.230.09 |
| 3 | 2 | Impulse line Ø 12 | ||
| 4 | 1 | 3 valve manifold PN 400 inlet: tube fitting 12S |
S341.36.125 | S341.36.225 |
| 5 | 1 | Accesscory kit consisting of: mounting bracket, screws and washers |
S006.42.100.02 | S006.42.200.02 |
| 6 | 2 | Accessory kit for mounting on 2" NB pipe consisting of: 'U' bolt, washers and nuts |
S006.42.105 | S006.42.205 |
| 7 | 1 | Accessory kit consisting of: screws, washers and seal rings |
catalogue page 8.00 | |
| 8 | 1 | Instrument | ||