Standard Design
Your Benefits
|
Screwed Bonnet
|
Tightness Class for VariAS-Blocks at Room Temperature (RT) (-29°C to 40°C [-20°F to 104°F])
Double Block & Bleed (Ball / Needle / Ball)
Ball Seat | Packing Ball Valve | Packing Needle Valve | Tightness Class | ||
C01 205 Cycles* |
C02 1,500 Cycles |
C03 2,500 Cycles |
|||
Reinforced PTFE | PTFE | PTFE / Reinforced PTFE | Class A | Class A | Class B |
Reinforced PTFE | Graphite | Graphite / FKM O-Ring | Class A | Class B | |
PEEK | PTFE | PTFE / Reinforced PTFE | Class A | Class A | Class B |
PEEK | Graphite | Graphite / FKM O-Ring | Class A | Class B | |
Reinforced PTFE | Lip Seal | Graphite / FKM O-Ring | Class A | Class A | Class A |
PEEK | Lip Seal | Graphite / FKM O-Ring | Class A | Class A | Class A |
Reinforced PTFE | O-Ring | Graphite / FKM O-Ring | Class A | Class A | Class A |
PEEK | O-Ring | Graphite / FKM O-Ring | Class A | Class A | Class A |
Metal Seated | Graphite | Graphite / FKM O-Ring | Class A | Class B |
* Several Stem Seals meet the requirement of ISO 15848-1, Edition 2006. These are more stringent than these of the current Edition 2015:
– Tightness values are reduced from Edition 2006 to 2015 by the factor of 10.
– Numbers of cycles are reduced from 500 to 205.
Note: The above mentioned table is only valid for Double Block & Bleed Valves (Ball / Needle / Ball). For other types please contact the factory.
Tightness Class for VariAS-Blocks at 200°C (RT to 200°C [-RT to 392°F])
Double Block & Bleed (Ball / Needle / Ball)
Ball Seat | Packing Ball Valve | Packing Needle Valve | Tightness Class | ||
C01 205 Cycles* |
C02 1,500 Cycles |
C03 2,500 Cycles |
|||
Reinforced PTFE | PTFE | PTFE / Reinforced PTFE | Class B | On request | |
Reinforced PTFE | Graphite | Graphite / FKM O-Ring | Class B | Class B | On request |
PEEK | PTFE | PTFE / Reinforced PTFE | Class B | On request | |
PEEK | Graphite | Graphite / FKM O-Ring | Class B | Class B | On request |
Reinforced PTFE | Lip Seal | Graphite / FKM O-Ring | Class B | On request | |
PEEK | Lip Seal | Graphite / FKM O-Ring | Class B | On request | |
Reinforced PTFE | O-Ring | Graphite / FKM O-Ring | Class B | On request | |
PEEK | O-Ring | Graphite / FKM O-Ring | Class B | On request | |
Metal Seated | Graphite | Graphite / FKM O-Ring | Class B | Class B | On request |
* Several Stem Seals meet the requirement of ISO 15848-1, Edition 2006. These are more stringent than these of the current Edition 2015:
– Tightness values are reduced from Edition 2006 to 2015 by the factor of 10.
– Numbers of cycles are reduced from 500 to 205.
Note: The above mentioned table is only valid for Double Block & Bleed Valves (Ball / Needle / Ball). For other types please contact the factory.